What was found
RT O/B FLAP I/B FWD HINGE (WING SIDE) LOWER MOUNT O/B HOLE SURFACE FOUND WITH CORROSION. LOWER MOUNT O/B HOLE SURFACE (7 HOLE) REWORKED AND FOUND EXCEED LIMIT AS PER CMM 57-44-08. EXISTING THICKNESS: 0.434", MATERIAL REMOVED FWD FACE: 0.008", AFT FACE: 0.009", REMAINING THICKNESS: 0.417", MINIMUM ALLOWABLE THICKNESS: 0.423". REPAIR SHIM FABRICATED AND INSTALLED AS PER EA 1-5750-T0340973 PART 1 STEP 1. REPAIR CLASSIFIED AS MINOR PER GMM 6-2-100. REFER TO MASTER EA 1-5750-T0340973 PART 1 AND SNRM NR N00535 FOR WORK DETAILS.