What was found
RT O/B FLAP O/B FWD HINGE (WING SIDE) LOWER MOUNT O/B HOLE BORE FOUND WITH CORROSION. FWD HINGE (WING SIDE) LOWER MOUNT O/B HOLE BORE REWORKED AND FOUND EXCEED LIMIT AS PER CMM 57-44-09. EXISTING HOLE DIA 0.597", FINAL HOLE DIA 0.613", MAXIMUM ALLOWABLE HOLE DIA 0.584". SHOULDER BUSHING FABRICATED AND INSTALLED AS PER EA 1-5750-T0341053 PART 1 STEP 2B AND STEP 2. REPAIR CLASSIFIED AS MINOR PER GMM 6-2-100. REFER TO MASTER EA 1-5750-T0341053 PART 1 AND SNRM NR N00509 FOR WORK DETAILS.