What was found
RT O/B FLAP O/B FWD HINGE (WING SIDE) LOWER MOUNT I/B HOLE SURFACE FOUND WITH CORROSION. FWD HINGE (WING SIDE) LOWER MOUNT I/B HOLE SURFACE REWORKED AND FOUND EXCEED LIMIT AS PER CMM 57-44-09. EXISTING THICKNESS: 0.435". MATERIAL REMOVED: 0.007" (FWD), 0.024" (AFT). REMAINING THICKNESS: 0.404". MINIMUM ALLOWABLE THICKNESS: 0.408". REPAIR SHIM FABRICATED AND INSTALLED AS PER EA 1-5750-T0341053 P1 STEP 2. REPAIR CLASSIFIED AS MINOR PER GMM 6-2-100. REFER TO MASTER EA 1-5750-T0341053 P1 AND SNRM NR N00509 FOR WORK DETAILS.