What was found
SHORTLY AFTER TAKE OFF FROM AFW RECEIVED ECAM FOR YELLOW SYSTEM RSV OVERHEAT. COMPLIED WITH ECAM AND CHECK LIST OVERHEAT LIGHT REMAIN ON UNTIL AFTER LANDING AT LAX. R&R RESERVOIR OVERHEAT MONITORING UNIT, OP TESTS GOOD. RAN ENGINE AND NO FAULTS. REF MM 29-33-12-04, MM 29-33-00-05, JRH CHP 5/6, TSM 29-33, ASM 29-33-00, IPC 29-33-01-01 ITEM 050.