What was found
EXISTING REPAIR AT MAIN DECK CARGO FLOOR SEAT TRACK STA 5-0 TO STA 5-43 X= 47.5 L. EXISTING REPAIR AT MAIN DECK CARGO FLOOR SEAT TRACK EVALUATED AND FOUND DAMAGED WITH CHAFING MARK AT STA 5-11, X= 47.5 L AND FOUND EXCEEDED LIMIT AS PER SRM 53-00-52-1A FIGURE 101 ALLOWABLE DAMAGE 1. FLOOR SEAT TRACK, CARRIED OUT REPAIR AS PER SRM 53-00-52-2R REPAIR 1 FIGURE 201, EO 1-5100-7-5001 B6. ACCOMPLISHED. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.