What was found
LT ENG STRUT OH DET 1 EICAS MESSAGE ON STATUS PAGE DURING CLIMB OUT TO 360. FOUND THERMAL SWITCH S10196 GIVING AN OVERHEAT DETECTION INDICATION BEFORE TEMPERATURE THRESHOLD. REMOVED AND REPLACED THERMAL SWITCHES S10194, S10195, AND S10196 FOR THE LEFT STRUT OVERHEAT LOOP 1, OPS CHECK GOOD IAW AMM 26-12-01-4.