Service difficulty report · Thermal Switch · Boeing 7572S7

Difficulty date
August 2, 2018
Submitted
August 14, 2018
Operation
Air carrier
Aircraft
N926FD
Make and model
Boeing 7572S7
Aircraft serial
23323
Aircraft time
95,160 hours, 37,307 cycles
Part
Thermal Switch
Part number
9750304003
Condition
Failed
Location
Lt Engine
Stage of operation
CL
How discovered
O
Nature of condition
N
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

LT ENG STRUT OH DET 1 EICAS MESSAGE ON STATUS PAGE DURING CLIMB OUT TO 360. FOUND THERMAL SWITCH S10196 GIVING AN OVERHEAT DETECTION INDICATION BEFORE TEMPERATURE THRESHOLD. REMOVED AND REPLACED THERMAL SWITCHES S10194, S10195, AND S10196 FOR THE LEFT STRUT OVERHEAT LOOP 1, OPS CHECK GOOD IAW AMM 26-12-01-4.