What was found
MAIN DECK RIGHT, AFT FLOOR SEAT TRACK AT BS 1871, RBL 75.25, FOUND THE FLANGE CORRODED. THE CORROSION WAS REMOVED AND FOUND TO EXCEED LIMITS IAW SRM 53-00-52-1A, FIG 101, ALLOWABLE DAMAGE 1. THE SEAT TRACK WAS REPAIRED BY A SECTIONAL REPLACEMENT FROM BS 1860 TO 1887 IAW SRM 53-00-52-2R, FIG 201, REPAIR 1. THE REPAIR WAS CLASSIFIED AS MAJOR IAW GMM 6-2-100.