What was found
RT WING O/B FLAP ASSY O/B FWD HINGE (WING SIDE) LOWER MOUNT O/B BORE CORROSION. HINGE LOWER MOUNT OUTBD BORE (NR 3 HOLE) REWORKED AND FOUND EXCEED LIMIT AS PER CMM 57-44-09, EXISTING HOLE DIA 0.596", FINAL HOLE DIA 0.612" MAXIMUM ALLOWABLE HOLE DIA 0.584", SHOULDER BUSHING FABRICATED AS PER EA 1-5750-127785 A P2 STEP 1A AND INSTALLED AS PER CMM 57-44-09 AND EA 1-5750-127785 A P2 STEP 1. REPAIR CLASSIFIED AS MINOR PER GMM 6-2-100.