What was found
MAIN DECK CARGO COMPT FLOOR PANEL OPEN UP FOR SUPRORT REPAIR FOUND SEAT TRACK FLANGE CORROSION AT STA 1681, X= 8.5. CORROSION REMOVED 0.066", REMAIN 0.014", MATERIAL THK 0.080" AND FOUND EXCEEDED LIMIT PER SRM 53-00-52-1A FIG 101 ALLOWABLE DAMAGE 1 AND EXCEEDED LIMIT SEAT TRACK REPAIRED PER SRM 53-00-52-2R FIG 201 REPAIR 1 AT CABIN STA 1671 TO STA 1711 X= 8.5. REPAIR CLASSIFIED AS MAJOR PER GMM6-2-100.