As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOORBEAM CORROSION RBL 64 AT BS 900-1020. REMOVED CORROSION AT ABOVE LOCATION IAW SRM 51-10-02 REV 124. MEASURED AND EVALUATED CLEANUP IAW SRM:53-40-13-1A ALLOWABLE DAMAGE 1 FIG 101 DET VII REV 124 AND FOUND OUT OF LIMITS. INSTALLED NEW CREASE BEAM BETWEEN BS 900-1020 RBL 64 IAW SRM 51-40-02 REV 124 AND DRAWING NR 144N5140.