What was found
LT WING O/B FLAP O/B FWD (WING SIDE) HINGE LOWER MOUNT I/B HOLE BORE CORROSION. HINGE LOWER MOUNT I/B HOLE BORE (NR 3 HOLE) REWORKED AND FOUND EXCEED LIMIT PER CMM 57-44-09. EXISTING HOLE DIA 0.584", FINAL HOLE DIA 0.596", MAXIMUM ALLOWABLE HOLE DIA 0.584", SHOULDER BUSHING FABRICATED & INSTALLED PER EA 1-5750-T0342059 P1 STEP 1B & INSTALLED PER CMM 57-44-09 & EA 1-5750-T0342059 P1 STEP 1. REPAIR CLASSIFIED AS MINOR PER GMM6-2-100.