What was found
LT WING O/B FLAP I/B FWD (WING SIDE) HINGE LOWER MOUNT O/B HOLE BORE CORROSION. HINGE LOWER MOUNT O/B HOLE BORE (NR 7 HOLE) REWORKED & FOUND EXCEED LIMIT PER CMM 57-44-08. EXISTING HOLE DIA 0.709", FINAL HOLE DIA 0.729", MAXIMUM ALLOWABLE HOLE DIA 0.709". OVERSIZED BUSHING FABRICATED & INSTALLED PER CMM 57-44-08 & EA 1-5750-T0342122 P1 STEP 2B, 2C & STEP 2. REPAIR CLASSIFIED AS MINOR PER GMM6-2-100.