As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MAIN DECK CARGO FLOOR SUPPORT FOUND WITH CORROSION AT STA 1902 X = 57. FLOOR SUPPORT CORROSION REMOVED AND FOUND EXCEEDED LIMIT AS PER SRM 53-00-00-2R FIGURE 206. ORIGINAL THICKNESS: 0.188 INCH MATERIAL REMOVED: 0.100 INCH, REMAINING THICKNESS: 0.088 INCH. FLOOR SUPPORT REMOVED AND REPLACED AS PER SRM 51-31-01-OG, FABRICATED FLOOR SUPPORT AS PER DRAWING 7551 REVISION G. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.