What was found
MAIN DECK FLOOR SEAT TRACK AT STATION 5-10 X = - 47.5 FOUND CROWN DAMAGED. MAIN DECK FLOOR AT SEAT TRACK STATION 5-10 X = - 47.5 , DAMAGED CROWN EDGE BLEND OUT AND FOUND TO EXCEED LIMIT AS PER SRM 53-00-52-1A FIGURE 101 ALLOWABLE DAMAGE 1. CROWN DAMAGED SEAT TRACK REPAIRED BY SECTIONAL SEAT TRACK REPLACEMENT FROM EXISTING SPLICES STATION 5-0 / 1531 TO STATION 5-123 / 1531 X = - 47.5 AS PER SRM 53- 00-52-2R FIGURE 201 REPAIR 1. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.