MAIN DECK FLOOR SEAT TRACK AT STATION 5-93 X = - 47.5 FOUND CROWN DAMAGED. MAIN DECK FLOOR AT SEAT TRACK STATION 5-93 X = - 47.5 , DAMAGED CROWN EDGE AT SEAT TRACK BLEND OUT AND FOUND TO EXCEED LIMIT AS PER SRM 53-00-52-1A FIGURE 101 ALLOWABLE DAMAGE 1. CROWN DAMAGED SEAT TRACK REPAIRED BY SECTIONAL SEAT TRACK REPLACEMENT FROM EXISTING SPLICES STATION 5-0 / 1531 TO STATION 5-123 / 1531 X = - 47.5 AS PER SRM 53-00-52-2R FIGURE 201 REPAIR 1. REFER TO SPECIAL / NONROUTINE MAINTENANCE FORM N00695 FOR WORK DETAILS. REPAIR CLASSIFIED AS MAJOR PER GMM 6- 2-100.