What was found
MAIN DECK SEAT TRACK, EVIDENCE OF CORROSION ON UPPER SURFACE BS 344 TO BS 376 LBL 6.75. CORROSION REMOVED IAW SRM 51-10-02 REV 125 AND FOUND TO BE OUTSIDE ALLOWABLE LIMITS IAW SRM 53-00-52-1A FIG 101 DETAIL VIII REV 125. NOMINAL THICKNESS OF FLANGE =0.085", DEPTH REMOVED 0.020" MAX ALLOWABLE 0.017 BLEND MUST NOT BE LESS THAN 20X AWAY FROM AN EXISTING FASTENER, BLEND IS AT A FASTENER LOCATION. SEAT TRACK REPLACED IAW DWG 3504.