What was found
MAIN DECK FLOOR BEAM EVIDENCE OF CORROSION ON UPPER SURFACE BS376 BETWEEN LBL47 AND LBL55 AT FASTERNER HOLES CORROSION REMOVED IAW SRM 51-10-02 AND FOUND TO BE OUT OF LIMIT IAW SRM 53-00-511A NOTE B DETAIL II ORIGINAL THICKNESS 0.125" ,DEPTH OF BLEND=0.029", MAX ALLOWABLE=0.012" , AREA REPAIRED IAW FEDEX E.A.#:F-5321-T0342941 PART (1)