What was found
PLEASE EVALUATE EXISTING BLENDS ON LT WING UPPER SURFACE AT WS.748 TO WS761, 2 INCHES FWD OF REAR SPAR AND TRILING EDGE PANEL JOINT REMOVED CORROSION IAW SRM 51-10-02 REV 125. MEASURED AND EVALUATED BLEND OUTS IAW SRM 57-20-01-1A ALLOWABLE DAMAGE 4 REV 125 AND SRM 57-20-01-1A ALLOWABLE DAMAGE 1 FIGURE 101 TABLE 1 REV 125, AND FOUND TO BE OUTSIDE OF LIMITS DUE TO LOCATION OF DAMAGE. REPAIR CARRIED OUT IAW EA # F-5730-T0344299 P1.