What was found
SUSPECT CORROSION AT B/S 1180-1200 LBL 24.5 CORROSION REMOVED IAW SRM 51-10-02 REV 125 AND FOUND TO BE OUTSIDE LIMITS IAW SRM 53-00-52-1A. DETAIL VII REV 125. MAX ALLOWABLE CLEANUP LIMITS (X) = 20% THICKNESS, TRACK FLANGE THICKNESS = .0.085", MAX ALLOWABLE CLEANUP = 0.017" , MAX DEPTH OF CLEAN UP = 0.021" SEAT TRACK SECTION REPAIRED IAW SRM 53-00-52-2R REPAIR 3 REV 125 AND EA.#:F-5310- T0344052 P1