What was found
CORROSION ON 2L LOWER DOOR GATE FOUND OUTSIDE PERMITTED LIMITS IAW SRM 52-10-02- 1A, FIG 101, SHEET 7 , REV.125 REPLACE DOOR GATE IAW AMM 52-11-38-4 REV 122.7.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON 2L LOWER DOOR GATE FOUND OUTSIDE PERMITTED LIMITS IAW SRM 52-10-02- 1A, FIG 101, SHEET 7 , REV.125 REPLACE DOOR GATE IAW AMM 52-11-38-4 REV 122.7.