What was found
MAIN DECK CARGO AFT COMPARTMENT FLOOR CENTER FLOOR SUPPORT FOUND WITH CORROSION AT STATION 1971 X = - 2. MAIN DECK CARGO AFT COMPARTMENT FLOOR AT CENTER FLOOR SUPPORT STATION 1971 X = -2, CORROSION REMOVED AND FOUND TO EXCEED LIMIT AS PER SRM 53-00-00-2R FIGURE 206. CORRODED FLOOR SUPPORT REMOVED AND REPLACED AS PER SRM 51-31-01-0G AT STATION 1887 TO STATION 2007 X = -2. NEW FLOOR SUPPORT FABRICATED BY MACHINING AS PER DRAWING AGA7080 REVISION S. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.