What was found
RADIOGRAPHY INSPECTION CARRIED OUT AND FOUND CRACK APPROX IMATELY 1" IN LENGTH AT STA 6-0 LONGERON 1 LEFT AT AFT CENTER SPLICE BETWEEN FASTENER 5 AND 6 AS MARKED. MAIN DECK CABIN AT STATION 6-0 LONGERON 1 LEFT AT AFT CENTRE CRACKED SPLICE REMOVED AS PER SRM 51-31-01-0G. NEW SPLICE FABRICATED AS PER DRAWING ADA 8413 REV B, FABRICATED NEW SPLICE PROTECTED AND PAINTED AS PER SRM 51-21-01-0G. NEW FABRICATED SPLICE INSTALLED PER SRM 51-33-01-0G. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.