What was found
MAIN DECK AFT FLOOR SUPPORT AT STA 1887-2007 X=-2 FOUND CRACKED AS MARKED. MAIN DECK AFT CRACKED FLOOR SUPPORT AT STATION 1887- STATION 2007 X= -2 REMOVED PER SRM 51-31-01-0G. NEW FLOOR SUPPORT FABRICATED AS PER DWG AGA 7081 REV M. FABRICATED NEW FLOOR SUPPORT INSTALLED AS PER SRM 51-31-01-0G. REPAIR CLASIFIED AS MAJOR PER GMM 6-2-100.