As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
PDIS 977 25-60 3952 16JAN19 GSO OPEN U LOGPAGES:2922410 RED SLIDE ARMED INDICATOR DOES NOT EXTEND FULLY WHEN THE DOOR IS ARMED (L1 DOOR) FACT 16JAN19 14:48 ORD APPLIED DC-33 TO GIRT BAR FLOOR FITTINGS AND REPOSITIONED UPPER DOOR LINER. PERFORMED OPS. CHECK OF GIRT BAR AND DOOR SLIDE ARMING PER MM 52-11-25 .OPS. CHECKED NORMAL.