As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MAIN CARGO AT APPROX STA 1300 LBL 75 - 105 AFTER REMOVING TAPE AND NUT PLATES FOUND UNDER SIDE OF FLOOR SUPPORT HAS EXFOLIATION CORROSION. FABRICATED AND PROCESSED NEW FLOOR SUPPORT REF DWG AEA0412 (P/N S2929169) AND SRM 51-31-01 VOL II. TREATED FLOOR SUPPORT AND REG SRM 51-21-01 VOL II. INSTALLED NEW FLOOR SUPPORT REF DWG AEA0412 AND SRM 51-33-01 VOL II.