What was found
MAIN DECK FLOOR SEAT TRACK AT STATION 1611 X=-47.5 FOUND CORROSION. FOUND EXCEED LIMIT AS PER SRM 53-00-52-1A FIG 101 ALLOWABLE DAMAGE 1. CORRODED FLOOR SEAT TRACK REPAIRED BY SECTIONAL SEAT TRACK REPLACEMENT FROM STATION 1651 TO EXISTING SPLICE STATION 1531 X= -47.5 AS PER SRM 53-00-52-2R FIG 201 REPAIR 1. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.