What was found
CORROSION SHEAR WEB AFT WET AREA MAIN CABIN FLOOR STA 1691 RBL 10.0 REMOVED CORROSION ON MAIN DECK PLATE STA 1691, RBL 10 IAW SRM 51-10-02-OG. EVALUATED DAMAGED AREA, ORIG MAT = .071", REM MAT = .055",MAT LOSS = .016" FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51-1A, FIG 101, DET III. FABRICATED AND INSTALLED REPAIR DOUBLER AND SHIM AT STA 1690 TO 1697, RBL 9 TO RBL 15 IAW SRM 53-60-51-2R, FIG 201, DET I , REPAIR 2, ALT I.