What was found
CORROSION SHEAR WEB AFT AREA MAIN CABIN FLOOR STA 1703 RBL 45. REMOVED CORROSION ON MAIN DECK PLATE STA 1703, RBL 45 IAW SRM 51-10-02-OG, EVALUATED DAMAGE AREA, ORIG. MAT =.071", REM. MAT = .048", MAT LOSS = .023" FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51-1A, FIG 101, DET III, FABRICATED & INSTALLED REPAIR DOUBLER AND SHIM AT STA 1697 TO 1711, RBL 41 TO RBL 48 IAW SRM 53-60-51-2R, FIG 201, DET I, REPAIR 2, ALT I.