What was found
01 EACH FASTENER HOLE FOUND CRACK INDICATION DURING OPEN-HOLE HFEC INSPECTION AT LEFT HAND WING LOWER SKIN ACCESS DOOR CUTOUT BETWEEN STATION XORS = 690 AND STATION XORS = 700 REPAIR CARRIED OUT ON 01 EACH FASTENER HOLE AT LEFT HAND WING LOWER SKIN ACCESS DOOR CUTOUT BETWEEN STATION XORS 690 AND STATION XORS 700 AS PER SRM 57-20-02-2R FIGURE 201 REPAIR 5. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100. TO CARRY OUT INITIAL INSPECTION AT 2,000 FLIGHT CYCLES AFTER COMPLETION OF THIS REPAIR AND REPETITIVE INSPECTION AT EVERY 2,000 FLIGHT CYCLES BY HFEC INSPECTION METHOD PER SRM 57-20-02- 2R TABLE 201 REPAIR 5.