What was found
MAIN DECK COMPARTMENT AFT FLOOR PANEL SUPPORT FOUND WITH CORROSION AT STATION 1961 X = - 56 MAIN DECK COMPARTMENT AFT FLOOR PANEL SUPPORT AT STATION 1961 X = - 56 CORROSION REMOVED AND FOUND TO EXCEED LIMIT AS PER SRM 53-00-00-2R FIGURE 206 . CORRODED FLOOR PANEL SUPPORT REMOVED AND REPLACED FROM STATION 1887 TO STATION 2007 X = - 56 AS PER SRM 51-31-01-0G. FLOOR PANEL SUPPORT FABRICATED BY MACHINING AS PER DOUGLAS DRAWING AGA 7551 REVISION G . REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100 .