What was found
PDIS 915 29-02 1209 02MAY19 BUD OPEN LOGPAGES:2826538 ON SHORT FINAL PASSING 800' EXPIERENCE L HYD SYS PRESS/L HYD QTY RUDDER RATIO/ CONTINUED TO LANDING RWY 31L STOPPING ABEAM CHARLY DUE TO LOSS OF ACFT STEERING. TB LEFT HYD QTY LOST TO ZERO FOUND LEFT MAIN LANDING GEAR DOWN LOCK ACTUATOR HOSE LEAKING IPC 32-32-51-16. ITEM 345. P/N INSTALLED AS115-06K0232 WAS PRE EO F-2920-7-5001. P/N MUST BE 271N6119-1 POST EO F-2920-7-5001. TEMPORARY FLEX LINE INSTALLED PER AMM 20-10-10-8. LINE P/N 271N6119-1 FOR POST EO F-2920-7-5001 INSTALLED FOR TERMINATING ACTION.