What was found
PERFORM NDT INSPECTION RUDDER FOUND RT SIDE PONDING AS MARK REPAIRED THE RUDDER RT SIDE AS MARK PER SRM55-41-12/201 PARA31 & EA: 6-5540-T0346748 P1, TITLE: STABILIZERS - RUDDER - WATER INGRESS WAS FOUND ON RUDDER RH PANEL AROUND TRAILING EDGE SCREW. THE REPAIR WAS CATEGORY "B" AND WAS CLASSIFIED AS MAJOR PER GMM 6-2-100. THE FIRST INSPECTION THRESHOLD WAS 30000FC AFTER REPAIR EMBODIMENT. THE SUBSEQUENT INSPECTION INTERVAL WAS TBD. INSPECTION METHOD WAS TBD PER EA: 6-5540-T0346748.