Service difficulty report · Relay · Doug MD11F

Difficulty date
May 30, 2019
Submitted
May 30, 2019
Operation
Air carrier
Aircraft
N591FE
Make and model
Doug MD11F
Aircraft serial
48527
Aircraft time
82,687 hours, 18,218 cycles
System (JASC)
2422 · AC Inverter
Part
Relay
Part number
5D01231
Condition
Failed
Stage of operation
TO
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

PDIS 591 24-22 3282 30MAY19 MEM FACT U LOGPAGES:2989059 GOT LEVEL 1 EMERG PWR ON AFTER T/OFF. SELECTED EMERG PWR SWITCH TO OFF/WAITED 10 SECONDS/RESELECTED. ALERT REOCURRED 2 MINUTES LATER. SAME DESELCT/RESELECT. FACT 30MAY19 04:25 MEM U INTERROGATED EPCU FAULT REVIEW. NO FAULTS FOUND. PERFORMED EPCU R-T-S TEST REF 24-08-01-5. ALL TESTS PASSED. REPLACED RELAY R2-5156 REF FIM 24-24-00-2. PERFORMED EMERGENCY POWER TEST REF AMM 24-08-01-5. ALL TESTS PASSED. A/C OK FOR SERVICE.