As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
HYD 3 ELEV OFF ALERT, HYD 3 QUANTITY 4.9 GAL. HYD 3 QUANTITY CONTINUED TO 3.6 GAL AND TURNED ENG PUMPS OFF TO CONSERVE FLUID. TURN BACK ON PUMPS FOR LANDING AND RECEIVED HYD 3 QTY LO. FINAL QTY 1.6 GAL. REPLACED DAMAGED 'O' RING AND RING REF AMM 27-43-40-4 . LEAK AND OPS CHECK GOOD. A/C OK FOR SERVICE.