Service difficulty report · Charger · Doug MD11F

Difficulty date
June 28, 2019
Submitted
June 28, 2019
Operation
Air carrier
Aircraft
N528FE
Make and model
Doug MD11F
Aircraft serial
48623
Aircraft time
65,732 hours, 14,009 cycles
Part
Charger
Condition
Malfunctioned
Location
Master Battery
Stage of operation
CR
How discovered
V
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

LVL 1 " BATT CHARGER IONP" ON TAXI, FOUND BATT CHARGER CONNECTOR ON BATT CHARGER DIS-CONNECTED FROM BATT CHARGER...PERFORMED BATTERY CHARGER ADJ/TEST AND NOT FAULTS NOTED ALSO HAD APU RUNNING WITH LOAD APPLIED HAD NORMAL BATTERY CHARGING LIGHT COME ON AND WITH OFF AS NORMAL..BATTERIES AND BATTERY CHARGER OPS CH'S NORMAL ON GRND NOW..ALL PROCEDURES WERE IAW M/M 24-34-03-5-0..NO FAULTS ARE NOTED AT THIS TIME AND A/C IS OK FOR CONT'D SVC.