What was found
HYD 2 OFF ALERT AT 1 20 INTO FLIGHT. QUANITY 2.6 GAL REMAINING. DURING CONFIGURATION 3-2 RMP REPRESSURIZED HYD 2 NORMALLY. LANDED WITH 1.6 GAL REMAINING. FOUND #2 SYSTEM PRESSURE "TEST" LINE WITH A PIN HOLE. REMOVED AND REPLACED AYK7550-812 PIPE ASSY. LEAK CHECKS GOOD. SERVICED #2 HYDRAULIC SYSTEM. OK FOR SERVICE.