What was found
M/D FLOOR PANEL SUPPORT AT STA 595 X= -57.25 TO X = -61.75 FOUND CORRODED . MAIN DECK FLOOR PANEL SUPPORT AT STA 595 X= -57.25 TO X = -61.75 CORROSION REMOVED AND FOUND EXCEEDED LIMIT AS PER SRM 53-00-00-2R FIG 202 ALLOWABLE DAMAGE . MAT REMAINED : 0.020". CORRODED FLOOR SUPPORT AT STA 595 X = -57.25 TO X = -61.75 CARRIED OUT REPAIR AS PER SRM 53-00-52-2R FIG 201 REPAIR 5. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.