What was found
MAIN DECK FLOOR SEAT TRACK AT STATION 5-11 X = - 47.5 FOUND CROWN DAMAGED . MAIN DECK FLOOR AT SEAT TRACK STATION 5-11 X = - 47.5 , DAMAGED CROWN EDGE BLEND OUT AND FOUND TO EXCEED LIMIT AS PER SRM 53-00-52-1A FIGURE 101 ALLOWABLE DAMAGE 1 . CROWN DAMAGED SEAT TRACK REPAIRED BY SECTIONAL SEAT TRACK REPLACEMENT AT EXISTING SPLICES STATION 5-0 TO STATION 5-63 X = - 47.5 AS PER SRM 53-00-52-2R FIGURE 201 REPAIR 1 . REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100 .