What was found
EXISTING REPAIR FOUND ON FLOOR SUPPORT STRUCTURE BS 570 APPROX. LBL 10. REPAIR REQUIRES EVALUATION TO DETERMINE IF MAJOR OR MINOR AND IF REPAIR IS IN ACCORDANCE WITH FAA APPROVED DATA EVALUATION CARRIED OUT OF EXISTING REPAIR ON FLOOR SUPPORT STRUCTURE AT BS.570 APPROX LBL.10 IAW FEDEX EO F-5100-7-5001 PART 1 ATTACHMENT B AND ON VISUAL INSPECTION AND SRM REVIEW, THE REPAIR LAYOUT AT BS 570 APPROX LBL 10 WAS IDENTIFIED AS CONFORMING TO SRM REPAIR 53-00-53-2R REPAIR 1, THIS IS A CAT A MAJOR REPAIR.