What was found
LEFT WING - OUTBOARD FLAP VANE NUMBER 1 SUPPORT FITTING ECCENTRC HOLE BORE FOUND CORRODED. REWORKED AND FOUND EXCEED LIMIT IAW SRM 57-50-02-2R, REPAIR 5, FIGURE 201. OVERSIZED ECCENTRIC BUSHING FABRICATED IAW SRM 57-50-02-2R REPAIR 5 FIGURE 201, AND EA 1-5750-T0348962, PART 1, STEP 1A. REPAIR CLASSIFIED AS MINOR PER GMM 6-2-100.