What was found
04 EACH FASTENER HOLES (#8,#9,#11,#28) FOUND CRACK INDICATION DURING HFEC OPEN-HOLE INSPECTION AT RIGHT HAND WING LOWER SKIN ACCESS DOOR CUTOUT BETWEEN STA XORS = 683.4 AND STA XORS = 713.6. RIGHT HAND WING LOWER SKIN ACCESS DOOR CUTOUT BETWEEN STA XORS = 683.4 AND STA XORS = 713.6 CRACK AT 04 EACH FASTENER HOLES (#8,#9,#11,#28) CARRIED OUT REPAIR PER SRM 57-20-02-2R FIGURE 201 REPAIR 5. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100. TO CARRY OUT INITIAL INSPECTION AT 2,000 CYCLES AFTER COMPLETION OF THIS REPAIR AND REPETITIVE INSPECTION AT EVERY 2,000 CYCLES PER SRM 57-20-02-2R TABLE 201 FIGURE 202 REPAIR 5.