What was found
MAIN DECK AFTER FLOOR SUPPORT AT STATION 1887 - 2007 X = 2 FOUND CRACKED. MAIN DECK CRACKED AFTER FLOOR SUPPORT AT STATION 1887 TO STATION 2007 X = 2 REMOVED AND REPLACED WITH FABRICATED FLOOR SUPPORT AS PER SRM 51-31-01-OG. FLOOR SUPPORT FABRICATED BY MACHINING AS PER DRAWING AGA 7081 REV M. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.