What was found
RIGHT WING, WING SIDE OUTBOARD FLAP OUTBOARD HINGE PIVOT HOLE BORE FOUND CORRODED. WORKED THE CORROSION AND FOUND EXCEED LIMITS IAW CMM 57-44-09. OVERSIZED BUSHING FABRICATED AND INSTALLED IAW CMM 57-44-09 AND EA 1-5750-T0349824, PART 1, STEP 3B, AND STEP 3, REPAIR CLASSIFIED AS MINOR IAW GMM 6-2-100.