What was found
LEFT WING, WING SIDE OUTBOARD FLAP INBOARD HINGE LOWER MOUNT, OUTBOARD BORE FOUND CORRODED. THE CORROSION WAS WORKED, AND FOUND TO EXCEED LIMITS IAW CMM 57-44-08. A SHOULDER BUSHING WAS FABRICATED IAW EA 1-5750-T0349887, PART 1, STEP 3B, AND INSTALLED IAW CMM 57-44-08, AND EA 1-5750-T0349887, PART 1, STEP 3. THE REPAIR WAS CLASSIFIED AS MINOR IAW GMM 6-2-100.