What was found
RIGHT WING, WING SIDE OUTBOARD FLAP OUTBOARD HINGE LOWER MOUNT OUTBOARD BORE FOUND CORRODED. THE CORROSION WAS WORKED AND FOUND TOE EXCEED LIMITS IAW CMM 57-44-09. A SHOULDER BUSHING WAS FABRICATED AND INSTALLED IAW CMM 57-44-09, AND EA 1-5750-T0349824, PART 1, STEP 3A, AND STEP 3. THE REPAIR WAS CLASSIFIED AS MINOR IAW GMM 6-2-100.