What was found
LEFT WING, FLAP SIDE OUTBOARD FLAP INBOARD HINGE PIVOT INBOARD LUG HOLE BORE FOUND CORRODED. CORROSION REWORKED AND FOUND TO EXCEED LIMITS IAW CMM 57-52-04. AN OVERSIZE BUSHING WAS FABRICATED AND INSTALLED IAW CMM 57-52-04, AND EA 1-5750-T0349971, PART 1, STEP 1A, AND STEP 1. THE REPAIR WAS CLASSIFIED AS MINOR IAW GMM 6-2-100.