What was found
FORWARD CABIN FLOOR SUPPORT AT STATION 445, RBL 95 FOUND CORROSION. THE FLOOR SUPPORT WAS FOUND EXFOLIATED AND EXCEEDED LIMITS IAW SRM 53-00-00-2R, FIGURE 206 ALLOWABLE DAMAGE. A NEW FLOOR SUPPORT WAS FABRICATED IAW DRAWING ABA 7341, REVISION C . THE FLOOR SUPPORT WAS REMOVED AND RELACED FROM BS 380 TO 459 IAW SRM 51-31-01-0G. THE REPAIR WAS CLASSIFIED AS MAJOR IAW GMM 6-2-100.