What was found
RIGHT WING OUTBOARD FLAP, OUTBOARD FORWARD HINGE (WING SIDE) LOWER MOUNT, OUTBOARD NR 3 HOLE BORE CORRODED. THE HOLE BORE WAS REWORKED AND FOUND TO EXCEED LIMITS IAW CMM 57-44-09. A SHOULDER BUSHING WAS FABRICATED AND INSTALLED IAW CMM 57-44-09, AND EA 1-5750-T0350044, PART 1, STEP 1. THE REPAIR WAS CLASSIFIED AS MINOR IAW GMM 6-2-100.