What was found
LOWER CENTER CARGO COMPARTMENT BILGE AREA LONGERON 44 RIGHT FOUND CORROSION AT STATION 1661 TO 1681. CORROSION REMOVED AS PER SRM 51-21-01-OG AND FOUND EXCEEDED LIMIT AS PER SRM 53-00-00-2R FIGURE 205. LONGERON 44 RIGHT CORROSION AREA CARRIED OUT REPAIR AS PER EA 1-5310-T0350241 PART 1. CLASSIFIED AS MAJOR PER GMM 6-2-100.