What was found
HFEC INSPECTION CARRIED OUT AT PSE, LOWER VERTICAL STABILIZER SPAR. FOUND A CRACK INDICATION AT THE RIGHT FORWARD FLANGE OF THE REAR UPPER SPAR. THE RIGHT REAR SPAR CAP FORWARD FLANGE LOCATED AT UPPER SECTION OF THE NR 4 BANJO FITTING OF LOWER VERTICAL STABILIZER STATION Y= 2164 WAS CRACKED APPROXIMATELY 2.1 INCHES, TRIMMED IAW SRM 55-30-02-2R, FIGURE 201, REPAIR 5. REPAIRED IAW SRM 55-30-02-2R, FIGURE 202, REPAIR 5. THE REPAIR WAS CLASSIFIED AS MAJOR IAW GMM 6-2-100.